Amer Networks SRPM24 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Netzwerk-Switches Amer Networks SRPM24 herunter. Amer Networks SRPM24 network switch Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User Manual

SRPM24 24-port Managed PoE Midspan Switch User Manual VER 1.20

Seite 2

SRPM24 Hardware Description In this paragraph, the hardware spec, port, cabling information, and wiring installation will be described. Physical D

Seite 3 - CE Mark Warning

SRPM24 On Green The Ethernet port is connecting with the device.LINK Off -- No device attached. On Green The port is receiving or transmitting d

Seite 4 - Content

SRPM24 Power On Connect the power cord to the power socket on the rear panel of the 24-port Managed PoE Midspan switch. Connect the other side of th

Seite 5

SRPM24 Rack-mounted Installation The switch comes with a rack-mounted kit and can be mounted in an EIA standard size, 19-inch Rack. The Device can be

Seite 6 - Introduction

SRPM24 Network Application The 24-port Managed PoE Midspan switch can provides power to the PDs that follow the IEEE 802.3af standard in the network.

Seite 7 - Software Features

SRPM24 Console Management Connecting to the Console Port 1. Attach one end of the supplied RS-232 cable to PC or terminal and the other end to the c

Seite 8

SRPM24 Login in the Console Interface When the connection between the device and PC is ready, turn on the PC and run a terminal emulation program or

Seite 9 - Package Contents

SRPM24 CLI Management The system supports the console management—CLI command. After you log in on to the system, you will see a command prompt. To e

Seite 10 - Hardware Description

SRPM24 Commands Set List User EXEC D Privileged EXEC E Global configuration C PoE P UPS U Sy

Seite 11 - Rear Panel

SRPM24 default C Restore to default SRPM24(config)#default username [Username] C Change a login username. (maximum 10 words) SRPM24(config)# username

Seite 12 - Attaching Rubber Feet

Notice The contents of this manual are based on the table below listing firmware version, software kernel version, and hardware version. If the f

Seite 13 - Rack-mounted Installation

SRPM24 strings [Community] string. strings public TFTP Commands Set Commands Level Description Defaults Example copy flash:config.text tftpC Save c

Seite 14 - Network Application

SRPM24 smtp password [password] C Configure authentication password SRPM24(config)#smtp password 123456 smtp recept-mail-address [1~4] [Mail address]

Seite 15 - Console Management

SRPM24 power-management [1~5] P Set power management mode. SRPM24(poe)#power-management 5 show status P Shows PoE status. SRPM24(poe)#show status sh

Seite 16

SRPM24 Web-Based Management This section introduces the configuration and functions of the Web-Based management. About Web-based Management There

Seite 17 - CLI Management

SRPM24 3. The login screen will appear right after 4. Key in the user name and password. The default user name and password are the same as ‘admin

Seite 18 - System Commands Set

SRPM24  System Name: Displays the system name of the managed PoE Midspan switch.  System Description: Describes the managed PoE Midspan switch. 

Seite 19 - SNMP Commands Set

SRPM24 User can configure the IP Settings and DHCP client function in here.  DHCP Client: Enable or disable the DHCP client function. When DHCP cli

Seite 20 - TFTP Commands Set

SRPM24 Security Manager System Log Configure the system event mode to collect system log.  System Log Client Mode: Select the system log mode—D

Seite 21 - PoE Commands Set

SRPM24 System Log PoE The article of PoE contains 5 sub-items, such as follows: ¾ PoE Status ¾ Controller Temperature ¾ PoE Power Manage ¾ PoE

Seite 22 - UPS Commands Set

SRPM24  Current: Displays the loading current (ampere).  System Power Limit: Key in the system power limit.  IEEE 802.3af Pre-standard: Enable o

Seite 23 - Web-Based Management

SRPM24 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC r

Seite 24 - System Information

SRPM24  Click Refresh to refresh the current state information.  And then, click Apply PoE Power Manage PoE Power Manage  Total Allocated Pow

Seite 25 - System IP Configuration

SRPM24 Consumption - sum of power consumed by all ports. Class - sum of all ports power according to their class, except for class 0 & 4 for

Seite 26 - Security Manager

SRPM24 PoE Port Status  Port: Displays the port number.  Status: Displays the status of the port.  Forward Power: Displays the forwarding power wh

Seite 27 - System Log

SRPM24 ¾ Email Alert ¾ IP Security UPS Status Power Status  Input Voltage: Displays the real, minimum, and maximum input voltage.  Output Vo

Seite 28 - PoE Status

SRPM24 SNTP Configuration User can configure the SNTP (Simple Network Time Protocol) settings. The SNTP allows user to synchronize device clocks in th

Seite 29 - Controller Temperature

SRPM24 ALA - Alaskan Standard -9 hours 3 am HAW - Hawaiian Standard -10 hours 2 am Nome, Alaska -11 hours 1 am CET - Central European FWT - Fren

Seite 30 - PoE Power Manage

SRPM24 Use this page to define management stations as trap managers and to enter SNMP community strings. You can also define a name, location and cont

Seite 31 - PoE Port Configuration

SRPM24  RW: Read write. Enables requests accompanied by this community string to display MIB-object information and to set MIB objects.  Click Add

Seite 32 - MISC Configuration

SRPM24  Authentication: Tick the checkbox to enable this function, configuring the email account and password for authentication (when Email Alert e

Seite 33 - UPS Status

SRPM24 security. Only these 10 IP addresses can access and manage the device through the HTTP/Telnet service.  And then, click Apply button to apply

Seite 34 - SNTP Configuration

Content FCC Warning ... ii CE Mark Warning ...

Seite 35 - SNMP Configuration

SRPM24 Update Firmware  TFTP Server IP Address: Type in your TFTP server IP.  Firmware File Name: Type in the name of the firmware image file. 

Seite 36

SRPM24 Save Configuration Save Configuration is used to save the user configuration to permanent data. If users want to keep their configuration

Seite 37 - Email Alert

SRPM24 System reboot 41

Seite 39 - TFTP Firmware Update

SRPM24 Troubles shooting Incorrect connections To link the Managed PoE Midspan switch with other Ethernet device, you should use correct UTP/STP ca

Seite 40 - Configuration Backup

SRPM24 Diagnosing LED Indicators To assist in identifying problems, the device can be easily monitored through panel indicators, which describe

Seite 41 - System Reboot

SRPM24 Technical Specification Technical specifications of SRPM24 Standard IEEE802.3 10Base-T IEEE802.3u 100Base-TX IEEE802.3af Power over Ethernet

Seite 42 - System reboot

SRPM24 Power 400W switch power supply embedded. AC input 100~240V 50/60Hz, A (Maximum) DC input 48V Power Consumption 407 Watts (Maximum) @AC 110V Ve

Seite 43

SRPM24 ©Amer.com Corp. 1997-2007 All rights reserved. 47

Seite 44 - Troubles shooting

SRPM24 iv Preparing for Web Management ...22 System Login...

Seite 45

Introduction Power-over-Ethernet (PoE) eliminates the need to run AC power to other devices on a wired LAN. Using Power-over-Ethernet system instal

Seite 46 - Technical Specification

SRPM24 Features  24-port PoE Midspan switch with 1 10/100TX for system management  400W Fully Power supported  Supports 802.3af pre-standard P

Seite 47

SRPM24 SNMP Trap 1. Cold start 2. Warm start 3. Authorization fail 4. PD disconnect trap-PoE port event 5. DC disconnect trap-PoE port Event 6. Discon

Seite 48 - ©Amer.com Corp

SRPM24 SNTP Supports RFC2030 Simple Network Time Protocol SMTP Up to 4 email recipients Configuration Upload and Download Backup and restore configu